Mundo power supply cabinets, fault monitoring units , flash controllers, and light head controllers are designed for all types of lights and could be re-designed as a personilezed solution by project.
Building Warning Lights
Height | Red Lights Working at Night Only |
Below 45m | Low intensity Type A on the perimeter of the building every 45 meters max. |
45m up to 105m | Medium intensity type B at the top with intermediate levels of low intensity type B. |
105m up to 150m | Medium intensity light type A installed every 105m max. |
150m and above | Alternative: above a height of 150m, high intensity light every 105 max. |
Height | White Flashing Light for Day Mode and Red Lights for Night Model |
Below 45m | Low intensity Type A on the perimeter of the building every 45 meters max, with medium intensity type A Work daytime only . |
45m up to 105m | Medium Intensity type AB at the top with optional low intensity type B at the intermediate levels. |
105m up to 150m | Medium intensity light type A installed every 105m max. |
150m and above | Alternative: above a height of 150m, high intensity light every 105 max. |