Mundo power supply cabinets, fault monitoring units , flash controllers, and light head controllers are designed for all types of lights and could be re-designed as a personilezed solution by Project.
Broadcast/Telecom Warning Lights
Height | Red Lights Working at Night Only |
Below 45m | 1 or 2 low intensity Type A or B at the top. |
45m up to 105m | 2 low intensity type A at the top only working simultaneously or redudancy. |
105m up to 150m | 1 or 2 medium intensity type B at the top, with intermediate level low intensity type B. |
150m and above | 1 or 2 medium intensity type B at the top, with intermediate levels of medium intensity type B every 105 meters max, with between each level of medium intensity Low intensity type B in between level of medium intensity work or high intensity type type A can also work. |
Height | White Flashing Light For Day Mode and Red Lights For Night Model |
Below 45m | 1 or 2 white medium intensity Type A at the top. |
45 m up to 105m | 2 low intensity type A working at night only, and 1 medium type A working during daytime only at the top. |
105m up to 150m | 1 or 2 dual color medium intensity type AB at the top, with low intensity type B in between each level of medium intensity. |
150m and above | 1 or 2 dual color medium intensity type AB at the top with low intensity type B inbetween each level of medium intensity ,or high intensity type type A can also work. |